TL-SG2210MP
Switch Smart con 8 Porte Gigabit PoE+ e 2 Slot SFP | Jetstream by Omada
- Switch Gigabit PoE+ - Switch dotato di 10 porte Gigabit - 8 PoE+ e 2 SFP.
- Power Budget totale - Alimentazione PoE+ 802.3at/af-compliant fino a 150 W su tutte le 8 porte PoE+.*
- Dispositivo integrato Omada SDN* - La nuova soluzione Omada Software Defined Networking consente di gestire le reti Omada con modalità Hybrid Cloud e Full-Cloud. Integra Access Point della serie EAP, Router VPN SafeStream e Switch JetStream by Omada.
- App Omada - L'intuitiva app Omada, per dispositivi Android e iOS, consente di accedere da remoto alla rete tramite Cloud, in qualunque momento, ovunque ti trovi.
- Massima sicurezza - IP-MAC-Port Binding, ACL, Port Security, DoS Defend, Storm Control, DHCP Snooping, 802.1X, Radius Authentication, ecc.
- Ottimizzazione video/voce - Con funzionalità L2/L3/L4 QoS e IGMP snooping.
Learn more about TP-Link PoE technology >
Learn more about Omada Cloud SDN>
Software Defined Networking
Switch PoE+ per installazioni flessibili e reti altamente scalabili
Switch JetStream 10 Porte Gigabit: 2 SFP - 8 PoE+
TL-SG2210MP
-
Gestione centralizzata in Cloud
Dispositivo integrato Omada SDN
-
Funzionalità Layer L2
L2/L3/L4 QoS, ACL, IGMP Snooping
-
Massima sicurezza
LAN Area Investment Protection
-
Supporto PoE+
8 Porte PoE+ - Power budget totale 150 W*
Omada SDN - Software Defined Networking
Omada SDN è la soluzione Software Defined di TP-Link che offre soluzioni wireless e cablate ideali per strutture alberghiere e sanitarie, edifici scolastici, aziende, spazi pubblici e molto altro. Omada SDN integra una gamma completa di dispositivi - Access Point, Switch, Gateway e Hardware Controller - in una soluzione altamente scalabile con gestione Full-Cloud e Hybrid-Cloud.
Wall
Plate Outdoor Nuova interfaccia di gestione Hardware Controller Gestione Full-Cloud
Case History
-
Istituto Superiore Statale Del Rosso - Da Verrazzano
TP-Link Professional Solution in ambito Education per Istituto Superiore Statale Del Rosso - Da Verrazzano. Progetto realizzato da TP-Link Partner Fans Computer.
Istituto Superiore Statale Del Rosso - Da Verrazzano
TP-Link Professional Solution in ambito Education per Istituto Superiore Statale Del Rosso - Da Verrazzano. Progetto realizzato da TP-Link Partner Fans Computer.
-
Istituto Superiore Statale Del Rosso - Da Verrazzano
TP-Link Professional Solution in ambito Education per Istituto Superiore Statale Del Rosso - Da Verrazzano. Progetto realizzato da TP-Link Partner Fans Computer.
Istituto Superiore Statale Del Rosso - Da Verrazzano
TP-Link Professional Solution in ambito Education per Istituto Superiore Statale Del Rosso - Da Verrazzano. Progetto realizzato da TP-Link Partner Fans Computer.
CARATTERISTICHE HARDWARE | |
---|---|
Standard e protocolli | IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.3af, IEEE 802.3at, IEEE 802.3az, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1x, IEEE 802.1p |
Interfaccia | • 8× 10/100/1000 Mbps RJ45 Ports, all supporting PoE+ (Auto-Negotiation/Auto MDI/MDIX)• 2× 100/1000 Mbps SFP Slots |
Media | • 10BASE-T: UTP/STP category 3, 4, 5 cable (maximum 100m)• 100BASE-TX/1000Base-T: UTP/STP category 5, 5e or above cable (maximum 100m)• 100BASE-FX: MMF, SMF• 1000BASE-X: MMF, SMF |
Numero ventole | 1 |
Physical security lock | Yes |
Porte PoE+ | • Standard: 802.3at/af compliant• PoE+ Ports: 8 Ports• Power Supply: 150 W |
Dimensioni ( L x P x A ) | 294 x 180 x 44 mm |
Tipo di montaggio | Rackmount/Desktop |
Max Power Consumption | • 12.2 W (110 V / 60 Hz with no PD connected) • 173.9 W (110 V / 60 Hz with 150 W PD connected) |
Max Heat Dissipation | • 41.63 BTU/h (with no PD connected) • 539.35 BTU/h (with 150 W PD connected) |
PRESTAZIONI | |
---|---|
Capacità di switching | 20 Gbps |
Packet Forwarding Rate | 14.9 Mpps |
Tabella ARP | 8K |
Buffer (pacchetti) | 4.1 Mbit |
Jumbo frame | 9 KB |
CARATTERISTICHE SOFTWARE | |
---|---|
QoS (Quality of Service) | • 802.1p CoS/DSCP priority • 8 priority queues • Priority Schedule Mode - SP (Strict Priority) - WRR (Weighted Round Robin) • Queue Weight Config • Bandwidth Control - Port/Flow based Rating Limit • Smoother Performance • Storm Control - Multiple Control Modes(kbps/ratio) - Broadcast/Multicast/Unknown-Unicast Control |
Funzionalità L2 e L2+ | • DHCP Relay - DHCP VLAN Relay • DHCP L2 Relay • Link Aggregation - Static link aggregation - 802.3ad LACP - Up to 8 aggregation groups and up to 8 ports per group • Spanning Tree Protocol - 802.1D STP - 802.1w RSTP - 802.1s MSTP - STP Security: TC Protect, BPDU Filter/Protect, Root Protect • Loopback Detection • Flow Control - 802.3x Flow Control • Mirroring - Port Mirroring - CPU Mirroring - One-to-One - Many-to-One - Flow-Based - Ingress/Egress/Both • Device Link Detect Protocol (DLDP) • 802.1ab LLDP/ LLDP-MED |
L2 Multicast | • 511 IPv4, IPv6 shared multicast groups • IGMP Snooping - IGMP v1/v2/v3 Snooping - Fast Leave - IGMP Snooping Querier - Static Group Config • Multicast VLAN Registration (MVR) • Multicast Filtering • MLD Snooping - MLD v1/v2 Snooping - Fast Leave - MLD Snooping Querier - Static Group Config • Limited IP Multicast (256 profiles and 16 entries per profile) |
IPv6 Support | • IPv6 Dual IPv4/IPv6 • Multicast Listener Discovery (MLD) Snooping • IPv6 neighbor discovery (ND) • Path maximum transmission unit (MTU) discovery • Internet Control Message Protocol (ICMP) version 6 • TCPv6/UDPv6 • IPv6 applications - DHCPv6 Client - Ping6 - Tracert6 - Telnet (v6) - IPv6 SNMP - IPv6 SSH - IPv6 SSL - Http/Https - IPv6 TFTP |
VLAN | • VLAN Group - Max. 4K VLAN Groups • 802.1Q tag VLAN • MAC VLAN: 12 Entries • Protocol VLAN • GVRP • Voice VLAN |
ACL (Access Control List) | • Support up to 230 entries • Time-Range - Time Slice - Week Time-Range - Absolute Time-Range - Holiday • Time-based ACL • MAC ACL - Source MAC - Destination MAC - VLAN ID - User Priority - Ether Type • IP ACL - Source IP - Destination IP - IP Protocol - TCP Flag - TCP/UDP Source Port - TCP/UDP Destination Port - DSCP/IP TOS • IPv6 ACL • Combined ACL • Rule Operation - Permit/Deny • Policy Action - Mirror - Rate Limit - Redirect - QoS Remark • ACL Rules Binding - Port Binding - VLAN Binding • Actions for flows - Mirror (to supported interface) - Redirect (to supported interface) - Rate Limit - QoS Remark |
Sicurezza | • AAA • 802.1X - Port based authentication - MAC (Host) based authentication - Authentication Method includes PAP/EAP-MD5 - MAB - Guest VLAN - Support Radius authentication and accountability • IP/IPv6-MAC Binding - 512 Binding Entries - DHCP Snooping - DHCPv6 Snooping - ARP Inspection - ND Detection • IP Source Guard - 253 Entries - Source IP+Source MAC • IPv6 Source Guard - 183 Entries - Source IPv6 Address+Source MAC • DoS Defend • Static/Dynamic/Permanent Port Security - Up to 64 MAC addresses per port • Broadcast/Multicast/Unicast Storm Control - kbps/ratio control mode • Port Isolation • Secure web management through HTTPS with SSLv3/TLS 1.2 • Secure Command Line Interface (CLI) management with SSHv1/SSHv2 • IP/Port/MAC based access control |
MIBs | • MIB II (RFC1213) • Bridge MIB (RFC1493) • P/Q-Bridge MIB (RFC2674) • Radius Accounting Client MIB (RFC2620) • Radius Authentication Client MIB (RFC2618) • Remote Ping, Traceroute MIB (RFC2925) • Support TP-Link private MIBs • RMON MIB(RFC1757, rmon 1,2,3,9) |
GESTIONE | |
---|---|
Omada App | Yes |
Centralized Management | • Omada Cloud-Based Controller• Omada Hardware Controller (OC300)• Omada Hardware Controller (OC200)• Omada Software Controller |
Cloud Access | Yes (Through OC300, OC200, Omada Cloud-Based Controller, or Omada Software Controller) |
Management Features | • Web-based GUI • Command Line Interface (CLI) through telnet • SNMPv1/v2c/v3 • SNMP Trap/Inform • RMON (1,2,3,9 groups) • SDM Template • DHCP/BOOTP Client • Dual Image, Dual Configuration • CPU Monitoring • Cable Diagnostics • EEE • SNTP • System Log |
ALTRO | |
---|---|
Certificazione | CE, FCC, RoHS |
Contenuto della confezione | • TL-SG2210MP• Power Cord• Installation Guide• Rackmount Kit• Rubber Feet |
Requisiti di sistema | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10, MAC® OS, NetWare®, UNIX® or Linux. |
Ambiente | • Operating Temperature: 0–50 ℃ (32–122 ℉); • Storage Temperature: -40–70 ℃ (-40–158 ℉) • Operating Humidity: 10–90% RH non-condensing • Storage Humidity: 5–90% RH non-condensing |
*Il calcolo del Power Budget PoEsi basa su test di laboratorio. Le prestazioni possono variare in base a limitazioni dei client e fattori ambientali.
* Verifica a questo link le funzionalità switch disponibili con Omada SDN.